Marine Heat Exchanger Plate

Marine Heat Exchanger Plate

Plate heat exchanger plates are specially designed for isolating media and conducting heat exchange, and are an important component of plate heat exchangers. Its main materials include stainless steel (SUS304/316), titanium and titanium palladium (Ti/Ti Pd), with a typical thickness of 0.5MM.
Send Inquiry
Description
Technical Parameters
Product Introduction

 

Marine Heat Exchanger Plate is a metal plate component installed in a marine plate heat exchanger. It is used to achieve heat transfer between fluids at different temperatures. It forms a fluid channel through a corrugated structure, allowing the cold and hot media to flow on both sides of the plate and complete the heat exchange process.

 

Product Details

 

Name

Plate

Category

Marine heat exchanger

Brand

ALFA LAVAL/GEA/APV/SONDEX/DONGHWA/TRANTER

Specification

All specifications are available

Material

Ti. 0.5/sus 316

Place of original

High quality equivalent parts

Packing

Standard packing

Condition

Brand new

Terms of delivery

Exw

Price

To be negotiated

Ports

China ports and other ports in the world

 

Main Offered Models

 

ALFA LAVAL
* A3,A10,A15,AK20,M3,M6,M10,M15,M20M,MX25B/M,M30
P22,P26,P31,P32,P36,TL6B,TL10B,T20B/M,TS20M,TS6M,JWP26,JWP36
GEA
* NT50T,NT50M,NT50X,NT100T,NT100M,NT100X,NT150S,NT150M,NT150L,NT250S,NT250L,NT350S
VT10,VT20,VT40,VT80,VT20P,VT80M
SONDEX
*S4,S7,S8,S9,S14,S15,S15,S21,S22,S30,S37,S39,S41,S43,S47,S50,S62,S65,S81,S83,S121
SFD13,SFD22,SFD35,SF25,SF123
APV
A055,A085, H17-C,J060,J092,J107,R5-R, R5-L
M60,M92,M107,N35-C,N35-G,N50,SR14AP,K71-C,K71-G,Q030D,Q030E,Q055,SR1,SR2,SR6
TRANTER
* GX-12,GX-12P1,GX-018,GX-26,GC-26,GX42,GX-60,GX-100,GX-145 T

 

Main Supplied Range

 

Plate and gasket

 

Advantages

 

Titanium and stainless steel composite structure
The plates are made of Ti 0.5 and SUS 316 stainless steel. The corrosion rate of titanium in sodium chloride seawater is less than 0.01mm/year, while SUS 316 has good pitting resistance. The selected materials can passivate the membrane self-healing mechanism and resist the erosion of seawater, coolant and some chemicals under high temperature and high humidity conditions.

 

Plate structure enhances heat transfer efficiency
The plate design adopts high-angle fishbone corrugated channels to improve fluid disturbance and form a strong turbulent state. The average heat exchange efficiency between plates can reach 3500W/m²·K. The pressure drop is controlled within a reasonable range (usually <50kPa) without increasing the system circulation pressure.

 

Removable structure
The Marine Heat Exchanger Plate adopts a repeatable assembly design. The plates are equipped with clamping gaskets to form an independent sealing channel. When scaling or damage occurs, the plates can be replaced individually to avoid the scrapping of the entire machine. The plate thickness is 0.5mm, which ensures the structural strength while reducing the material consumption.

 

Delivery And Shipping Service

product-2508-1416

24*7 hours online, our services cover all main ports in the world, we can provide the cost and time saving logistics solution to our customers, to provide you with one stop comprehensive services.

 

 

FAQ

Q: What is the role of the corrugation design of the Marine Heat Exchanger Plate?

A: The corrugation design determines the degree of fluid disturbance, which affects the heat exchange efficiency and pressure drop. High-angle corrugations provide higher heat exchange efficiency but large pressure drop, while low-angle corrugations are suitable for high-flow and low-resistance systems. When purchasing, efficiency and energy consumption should be balanced according to the heat exchange conditions.

Q: How to determine whether the plate needs to be replaced?

A: Regularly check for cracks, corrosion perforation, surface scaling or plate deformation. If the plate is poorly sealed, leaks locally or cannot be restored to a smooth surface after cleaning, it indicates that its performance has declined and should be replaced in time to avoid the risk of reduced overall efficiency or leakage.

Q: What are the requirements for daily maintenance and cleaning?

A: It is recommended to clean the plate every 3 to 6 months, especially when dealing with high-hardness water or salty process water. High-pressure water guns and chemical cleaning fluids (such as citric acid or EDTA) can be used to remove scale and impurities. Avoid using hard brushes or sharp tools during maintenance to prevent scratches on the plate surface that affect heat exchange efficiency.

Q: What should be paid attention to when installing the Marine Heat Exchanger Plate?

A: The plates must be installed in strict accordance with the original order to ensure that the corrugation direction is consistent. The alignment accuracy must be high to prevent the gasket from failing to seal. When tightening, the pressure must be applied diagonally and symmetrically to prevent uneven force from causing the plates to bend or the clamps to be loose. After installation, it is recommended to conduct a water pressure test to verify the sealing.

Hot Tags: marine heat exchanger plate, China marine heat exchanger plate suppliers, Marine Gate Valve, auxiliary engine, Marine Air Compressor Piston, Burner Ignition Electrode, aux boiler, Main Engine Cylinder Liner